Heat Seal Controls and Heat Seal Components used in new and upgraded Heat Sealing systems for packaging and similar applications. The unique heat seal technology employed is the product of more than 25 years of continuous development to produce consistent and repeatable heat seals. Perfect Heat Seals ... Everytime!
9 Steps To Heat Sealing Perfection

A systematic approach for improving performance while obtaining superior results with stronger, more attractive heat seals.

Transformer Selection
Size the transformer.

Transformers are an important part of the total system. Step-down transformers are used to reduce maximum voltage to a safe operating level as well as electrically isolate the heatsealing circuit from possible ground loops that could affect the performance of the system. Power transformer size and voltage tap selection depend upon the length, cross-section, and number of Heatseal Bands being controlled by one system. One system consists of one controller and one power transformer.

Power and Voltage Requirements
As the length of the Heatseal Band increases, the electrical resistance of the Heatseal Band increases. In order to get proper performance, the secondary voltage output of the transformer must be selected to produce the correct level of total power. The temperature of the Heatseal Band should ramp up at a rate not to exceed 1°C/mSec. If the secondary voltage supply is too high, the ramp-up rate will be too rapid and the controller will not respond properly.

“Thumb Rules” for Voltage and Power
Voltage
Optimum voltage selection depends on several variables. Application Engineers at
can assist you by calculating the preferred set-up using computer programs. This service is offered free of charge to the Resistron (RES) Heatseal Temperature Controller users. Call 610-759-8883.

A “Thumb Rule” for determining voltage is 1 to 1.5 volts/inch of band length. Wider and thicker bands should be calculated closer to 1 volt/inch.

Power — Transformer size in KVA
Once the voltage is determined, the power required at peak load (heat-up) can be calculated by use of the following formula.

Power (KVA) = Voltage2

Total Resistance X 1000
pad
Total Resistance = Length of Band (inches) X
Band Resistance (Ohms/inch)
Heatseal Band resistance is found on the chart...
Note — Maximum allowable KVA for RES-Controllers:
at 400 volt primary power supply is 8.0 KVA
at 230 volt primary power supply is 4.4 KVA
at 115 volt primary power supply is 2.2 KVA

Applications that require more power can be operated by use of a Booster System. Please contact the Application Engineering Staff for assistance.

The transformer’s secondary voltage selection is very important because the controller will go full “ON” when the controller is first activated. If the secondary voltage is too low, the ramp-up will be slow and the time required to reach the pre-set temperature will be too long. Alternatively, if the voltage is too high, the ramp-up rate may exceed 1°C/mSec. In this case, the controller will go into a switching mode, control will be unsatisfactory, and damage to the controller may result.

It is important not to exceed the recommended KVA rating of a transformer. The selection of a transformer that is not oversized will provide some protection against the possibility of damage in the event that an oversized Heatseal Band is installed.

TOSS Heatseal Power Transformers
offers special Heatseal Power Transformers with 115V, 230V, and 400V primary ratings. These specially wound multi-tap transformers provide a selection of secondary voltages to suit every need. Developed for high response, the transformers are designed to complement the Resistron (RES) Heatseal Temperature Controllers assuring trouble-free performance and easy system design and installation.

Continue to Step 9
Controller Selection
Pick the right controller for the job.

Back to the top

STEP 1
Heatseal Configuration
Determine what is expected from the seal.

STEP 2
Heatseal Band Selection
Select the proper Heatseal Band for the job.

STEP 3
Modes of Sealing
Which sealing mode is best for this application?

STEP 4
Heatseal Jaw Design
How to make a functioning Heatseal Jaw?

STEP 5
Heatseal Band Back-Ups & Jaw Facings
Select a facing for the jaw.

STEP 6
Anti-Stick Provisions
Keep the hot plastic from sticking.

STEP 7
Timing
When to heat and when to cool.

STEP 8
Transformer Selection
Size the transformer.

STEP 9
Controller Selection
Pick the right controller for the job.

CERTIFIED PERFORMANCE and VALIDATION/SUMMARY
How to make a functioning Heatseal Jaw


Contact us for
the following
information and
resources...

Controller Specifications

Heatseal Band & Supplies

Instruction Manual

Installation Guide

Troubleshooting Guide


9 Steps to
Heatsealing
Perfection Guide
Order your free copy online or call today...

610-759-8883


AND
are dedicated
to providing superior
heat sealing capability
to the packaging industry.

PACKAGE SEALING
MACHINES

Precision Heat Sealing Machines at PackworldUSA

© 2007 Toss Machine Components, Inc. | 539 South Main Street | Nazareth, PA 18064 USA
Phone: 610-759-8883 | Fax: 610-759-1766
Email us at: info@tossheatseal.com